{"id":1252,"date":"2015-04-28T19:20:14","date_gmt":"2015-04-28T17:20:14","guid":{"rendered":"http:\/\/biophysical-tools.de\/?page_id=1252"},"modified":"2021-09-29T20:22:35","modified_gmt":"2021-09-29T18:22:35","slug":"p2cs-selector","status":"publish","type":"page","link":"https:\/\/biophysical-tools.de\/de\/p2cs-selector\/","title":{"rendered":"P2CS-Selector Pressure Calculator"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_raw_code wpb_raw_html wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<center><b>\n<noscript>\nYou need JavaScript enabled to execute these calculations!\n<\/noscript>\n<\/b><\/center>\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div id=\"ts-vcsc-divider-8794267\" class=\"ts-divider-holder\"  data-border-width=\"1\" data-margin-top=\"-15\" data-margin-bottom=\"10\" style=\"margin-top: -15px; margin-bottom: 10px;\"><div class=\"ts-divider-lines\" style=\"width: 100%; border-bottom: 1px solid #eeeeee;;\"><div class=\"ts-divider-text left\" style=\"font-size: 20px; line-height: 25px;\"><div class=\"ts-left-help translation-block\" style=\"background: #ffffff; font-size: 20px; line-height: 25px; color: #676767; margin-top: 0.5px;\"><a class=\"ubermenu-target ubermenu-item-layout-default ubermenu-item-layout-text_only\" href=\"https:\/\/biophysical-tools.de\/de\/p2cs-selector\/\" target=\"_self\"><span class=\"ubermenu-target-title ubermenu-target-text\">Rechner f\u00fcr Versionsauswahl von P<sup>2<\/sup>CS<\/span><\/a><\/div><\/div><\/div><\/div>\n\t<div class=\"wpb_text_column wpb_content_element vc_custom_1630694495501\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Calculate the required\u00a0pressure difference to figure out\u00a0the recommended P<sup>2<\/sup>CS model for a given maximum flow rate determining the width, height or radius and length of your\u00a0microchannel and the viscosity of the fluid in use. For cylindrical microchannels width is not required, but still enter a non-zero \u201cfake\u201d number.<br \/>\nFor further information\u00a0about our patented Precision Pressure Controller P<sup>2<\/sup>CS please <a href=\"https:\/\/biophysical-tools.de\/de\/microfluidic-flow-control-precision-pressure-control-system\/\" target=\"_blank\" rel=\"noopener noreferrer\">click here.<\/a><\/p>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_raw_code wpb_raw_html wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<form method=\"POST\" action=\"\">\n<script type=\"text\/javascript\" src=\"\/js\/p2csselcalc.js\"><\/script>\n<style type=\"text\/css\">\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{font-family: 'Open Sans';font-size:14px;padding:0px 9px;border-style:solid;border-width:0px;overflow:hidden;word-break:normal;}\n.tg th{font-family: 'Open Sans';font-size:14px;font-weight:normal;padding:0px 9px;border-style:solid;border-width:0px;overflow:hidden;word-break:normal;}.tg .tg-0ord{text-align:right}\n.tg .tg-5y5n{background-color:#ecf4ff;height: 10px}\n.tg .tg-7nfe{background-color:#ecf4ff;text-align:right;height: 10px}\n<\/style>\n<table class=\"tg\" style=\"float:left; width:350px; margin-right:40px\">\n<tr>\n    <td class=\"tg-031e\">Width:<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"width\" value=\"0.10\" SIZE=6 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">mm<\/td>\n   \n  <\/tr>\n  <tr>\n    <td class=\"tg-031e\">Height (smaller than width) or diameter:<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"height\" value=\"0.10\" SIZE=6 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">mm<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-031e\">Length:<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"length\" value=\"1.00\" SIZE=6 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">cm<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-0ord\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-031e\">Viscosity<a href=\"https:\/\/biophysical-tools.de\/de\/h2o-viscosity\/\" target=\"_blank\" style=\"color: rgb(122,122,122)\"><font color=\"7a7a7a\"> (Calculator)<\/a><font color=\"1a1a1a\">:<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"viscosity\" value=\"0.950\" SIZE=6 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">mPa\u00b7s<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-031e\">Max needed flow rate:<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"mnfl\" value=\"10.00\" SIZE=6 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">\u00b5l\/sec<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-031e\" colspan=\"3\"><input type =\"BUTTON\" value=\"Calculate\" onclick=\"pres(this.form)\">&nbsp;&nbsp;<input type=\"BUTTON\" value=\"Reset form to default values\" onClick=\"this.form.reset(pres)\"<\/td>\n  <\/tr>\n<\/table>\n\n<table class=\"tg\" style=\"float:left; width:600px\">\n  <tr>\n    <th class=\"tg-031e\"><\/th>\n    <th class=\"tg-0ord\"><\/th>\n    <th class=\"tg-031e\"><\/th>\n    <th class=\"tg-031e\"><\/th>\n    <th class=\"tg-0ord\"><\/th>\n    <th class=\"tg-031e\"><\/th>\n  <\/tr>\n<tr>\n    <td class=\"tg-5y5n\" colspan=\"3\">Required pressure (approx) difference \u0394p in <br>cylindrical capillary (diameter):<\/td>\n    <td class=\"tg-5y5n\" colspan=\"3\">Recommended P<sup>2<\/sup>CS Version:<\/td>\n<\/tr>\n    <td class=\"tg-5y5n\"><img class=\"aligncenter  wp-image-1268\" src=\"http:\/\/biophysical-tools.de\/wp-content\/uploads\/2015\/04\/P2CSselectorCyltr.png\"  alt=\"\" width=\"100\" height=\"35\" \/><\/td>\n    <td class=\"tg-7nfe\"><INPUT STYLE=\"background-color:#ecf4ff; border:1px solid #436bb8; text-align:center; font-weight:bold;\" TYPE=\"text\" NAME=\"pressure1\" value=\"387\" SIZE=6 readonly=\"readonly\"<\/td>\n    <td class=\"tg-5y5n\">mbar<\/td>\n    <td class=\"tg-5y5n\"><a href=\"https:\/\/biophysical-tools.de\/de\/microfluidic-flow-control-precision-pressure-control-system\/\" target=\"_blank\"><img class=\"aligncenter size-medium wp-image-520\" src=\"http:\/\/biophysical-tools.de\/wp-content\/uploads\/2015\/09\/P2CS-lat-transp-300.png\" alt=\"\" width=\"100\" height=\"35\" \/><\/a><\/td>\n    <td class=\"tg-7nfe\"><INPUT STYLE=\"background-color:#ecf4ff; border:1px solid #436bb8; text-align:center; font-weight:bold;\" TYPE=\"text\" NAME=\"recVers1\" value=\"PM500\" SIZE=8 readonly=\"readonly\"<\/td>\n    <td class=\"tg-5y5n\"><\/td>\n<tr>   \n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n<\/tr>\n<tr> \n    <td class=\"tg-5y5n\" colspan=\"3\">Required pressure difference (approx) \u0394p in <br>rectangular channel (Width x Hight):<\/td>\n    <td class=\"tg-5y5n\" colspan=\"3\">Recommended P<sup>2<\/sup>CS Version:<\/td>\n<\/tr>    \n<tr> \n    <td class=\"tg-5y5n\"><img class=\"aligncenter  wp-image-1269\" src=\"http:\/\/biophysical-tools.de\/wp-content\/uploads\/2015\/04\/P2CSselectorRecttr-300x136.png\" alt=\"\" width=\"130\" height=\"60\" \/><\/td>\n    <td class=\"tg-7nfe\"><INPUT STYLE=\"background-color:#ecf4ff; border:1px solid #436bb8; text-align:center; font-weight:bold;\" TYPE=\"text\" NAME=\"pressure2\" value=\"269\" SIZE=6 readonly=\"readonly\"<\/td>\n    <td class=\"tg-5y5n\">mbar<\/td>\n    <td class=\"tg-5y5n\"><a href=\"https:\/\/biophysical-tools.de\/de\/microfluidic-flow-control-precision-pressure-control-system\/\" target=\"_blank\"><img class=\"aligncenter size-medium wp-image-520\" src=\"http:\/\/biophysical-tools.de\/wp-content\/uploads\/2015\/09\/P2CS-lat-transp-300.png\" alt=\"\" width=\"100\" height=\"35\" \/><\/a><\/td>\n    <td class=\"tg-7nfe\"><input style=\"background-color:#ecf4ff; border:1px solid #436bb8; text-align:center; font-weight:bold;\" type=\"text\" name=\"recVers2\" value=\"PM500\" size=\"8\" readonly=\"readonly\"><\/td>\n    <td class=\"tg-5y5n\"><\/td>\n <\/tr>\n <\/tr>  \n     <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\" colspan=\"3\"><\/td>\n    <td class=\"tg-031e\" colspan=\"3\"><\/td>\n \n<\/tr>  \n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n <\/tr><\/table>\n\n    \n\t\t<input type=\"hidden\" name=\"trp-form-language\" value=\"de\"\/><\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p><span style=\"color: #a5a5a5;\">There is no warranty of any kind regarding the accuracy or completeness of this\u00a0calculator\u00a0or your results, and the user assumes all risk of use.<br \/>\nUse of this\u00a0calculator\u00a0constitutes your acceptance of these terms.<\/span><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"You need JavaScript enabled to execute these calculations! P2CS-Selector Pressure Calculator Calculate the required\u00a0pressure difference to figure out\u00a0the recommended P2CS model for a given maximum flow rate determining the width, height or radius and length of your\u00a0microchannel and the viscosity of the fluid in use. For cylindrical microchannels width is not required, but still enter&hellip;","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":12,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/pages\/1252"}],"collection":[{"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/comments?post=1252"}],"version-history":[{"count":62,"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/pages\/1252\/revisions"}],"predecessor-version":[{"id":2644,"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/pages\/1252\/revisions\/2644"}],"wp:attachment":[{"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/media?parent=1252"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}