{"id":1403,"date":"2015-05-05T11:25:28","date_gmt":"2015-05-05T09:25:28","guid":{"rendered":"http:\/\/biophysical-tools.de\/?page_id=1403"},"modified":"2021-09-29T20:22:07","modified_gmt":"2021-09-29T18:22:07","slug":"p2cs-syringe-pump-comparison-calculator","status":"publish","type":"page","link":"https:\/\/biophysical-tools.de\/de\/p2cs-syringe-pump-comparison-calculator\/","title":{"rendered":"P2CS &#8211; Syringe Pump Comparison Calculator"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_raw_code wpb_raw_html wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<center><b>\n<noscript>\nYou need JavaScript enabled to execute these calculations!\n<\/noscript>\n<\/b><\/center>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div id=\"ts-vcsc-divider-6099015\" class=\"ts-divider-holder\"  data-border-width=\"1\" data-margin-top=\"-15\" data-margin-bottom=\"10\" style=\"margin-top: -15px; margin-bottom: 10px;\"><div class=\"ts-divider-lines\" style=\"width: 100%; border-bottom: 1px solid #eeeeee;;\"><div class=\"ts-divider-text left\" style=\"font-size: 20px; line-height: 25px;\"><div class=\"ts-left-help\" style=\"background: #ffffff; font-size: 20px; line-height: 25px; color: #676767; margin-top: 0.5px;\">P<sup>2<\/sup>CS \/ Spritzenpumpenvergleich - Rechner<\/div><\/div><\/div><\/div>\n\t<div class=\"wpb_text_column wpb_content_element vc_custom_1630694315934\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Compare the different stabilization times of syringe pumps and\u00a0our\u00a0Precision Pressure Control System P<sup>2<\/sup>CS\u00a0for a set value pressure step of 50mbar with pure water at 25 \u00b0C.\u00a0The calculated time estimates the time to reach 90% of the final flow rate.\u00a0Hysteresis and mechanical tolerances are not taken into account, but consider that these factors are degrading the response time even more.<br \/>\nFor further information\u00a0about our patented Precision Pressure Controller P<sup>2<\/sup>CS please <a href=\"https:\/\/biophysical-tools.de\/de\/microfluidic-flow-control-precision-pressure-control-system\/\" target=\"_blank\" rel=\"noopener noreferrer\">click here.<\/a><\/p>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_raw_code wpb_raw_html wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<form method=\"POST\" action=\"\">\n<script type=\"text\/javascript\" src=\"\/js\/syringecalc.js\"><\/script>\n<style type=\"text\/css\">\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{font-family: 'Open Sans';font-size:14px;padding:0px 9px;border-style:solid;border-width:0px;overflow:hidden;word-break:normal;}\n.tg th{font-family: 'Open Sans';font-size:14px;font-weight:normal;padding:0px 9px;border-style:solid;border-width:0px;overflow:hidden;word-break:normal;}.tg .tg-0ord{text-align:right}\n.tg .tg-5y5n{background-color:#ecf4ff;height: 10px}\n.tg .tg-5y5z{background-color:#ecf4ff;text-align:center;height: 10px}\n.tg .tg-7nfe{background-color:#ecf4ff;text-align:right;height: 10px}\n<\/style>\n<table class=\"tg\" style=\"float:left; width:340px; margin-right:40px\">\n <tr>\n    <td class=\"tg-031e\" colspan=\"3\"><b>Characteristics of the Microchannel and Fluid<\/b><\/td>\n  <\/tr>\n  <tr><td colspan =\"3\"><br><\/td><\/tr>\n<tr>\n    <td class=\"tg-031e\">Width:<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"width\" value=\"0.10\" size=7 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">mm<\/td>\n   \n  <\/tr>\n  <tr>\n    <td class=\"tg-031e\">Height (smaller than width) or Radius:<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"height\" value=\"0.01\" size=7 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">mm<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-031e\">Length:<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"length\" value=\"10.00\" size=7 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">mm<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-031e\"><\/td>\n    <td class=\"tg-0ord\"><\/td>\n    <td class=\"tg-031e\"><\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-031e\">Viscosity of H<sub>2<\/sub>O (25\u00b0C):<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right;background-color:#f5f5f5\" TYPE =\"text\" NAME=\"viscosity\" value=\"0.895\" size=7 readonly=\"readonly\";<\/td>\n    <td class=\"tg-031e\">mPa\u00b7s<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-031e\">Effective compressibility of H<sub>2<\/sub>O (25\u00b0C):<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right;background-color:#f5f5f5\" TYPE =\"text\" NAME=\"compr\" value=\"0.000046\" size=7 readonly=\"readonly\";\"<\/td>\n    <td class=\"tg-031e\">1\/bar<\/td>\n    <\/tr>\n\n    <tr><td colspan =\"3\"><br><\/td><\/tr>\n  <tr>\n    <td class=\"tg-031e\" colspan=\"3\"><input type =\"BUTTON\" value=\"Calculate\" onclick=\"pres(this.form)\">&nbsp;&nbsp;<input type=\"BUTTON\" value=\"Reset Form to default values\" onClick=\"this.form.reset(pres)\"<\/td>\n  <\/tr>\n  <\/table>\n  \n  <table class=\"tg\" style=\"float:left; width:340px; margin-right:40px\">\n   <tr>\n    <td class=\"tg-031e\" colspan=\"3\"><b>Characteristics of the Syringe Pump<\/b><\/td>\n  <\/tr>\n    <\/tr>\n  <tr><td colspan =\"3\"><br><\/td><\/tr>\n<tr>\n    <tr>\n    <td class=\"tg-031e\">Diameter Syringe (cyl. shape):<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"syrd\" value=\"5.00\" size=7 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">mm<\/td>\n  <\/tr>\n    <tr>\n    <td class=\"tg-031e\">Length Syringe (cyl. shape):<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"syrl\" value=\"10.00\" size=7 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">cm<\/td>\n  <\/tr>\n    <tr>\n    <td class=\"tg-031e\">Volume Syringe (cyl. shape):<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right;background-color:#f5f5f5\" TYPE =\"text\" NAME=\"syrv\" value=\"1.963\" size=7 readonly=\"readonly\";\"<\/td>\n    <td class=\"tg-031e\">ml<\/td>\n  <\/tr>\n      <tr>\n    <td class=\"tg-031e\">Material of syringe (effective compressibility):<\/td>\n    <td class=\"tg-0ord\"><div><select name=\"syrm\"><option value=\"0.0000005\">Steel<option selected value=\"0.01\">Plastics<option value=\"0.1\">Rubber<\/select><\/div><\/td>    \n    <td class=\"tg-031e\"><\/td>\n   <\/tr>\n  <\/table>\n\n<table class=\"tg\" style=\"float:left; width:340px; margin-right:40px\">\n   <tr>\n    <td class=\"tg-031e\" colspan=\"3\"><b>Characteristics of the Syringe Pump Tubing<\/b><\/td>\n  <\/tr>\n  <tr><td colspan =\"3\"><br><\/td><\/tr>\n<tr>\n <tr>\n    <td class=\"tg-031e\">Diameter tubing (cyl. Shape):<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"tubd\" value=\"1.00\" size=7 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">mm<\/td>\n  <\/tr>\n   <tr>\n    <td class=\"tg-031e\">Length tubing (cyl. Shape):<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right\" TYPE =\"text\" NAME=\"tubl\" value=\"20.00\" size=7 onClick=\"value=''\" onKeyup=\"this.value = this.value.replace(\/\\,\/, '.');\"<\/td>\n    <td class=\"tg-031e\">cm<\/td>\n  <\/tr>\n     <tr>\n    <td class=\"tg-031e\">Volume tubing (cyl. Shape):<\/td>\n    <td class=\"tg-0ord\"><INPUT STYLE=\"text-align:right;background-color:#f5f5f5\" TYPE =\"text\" NAME=\"tubv\" value=\"0.157\" size=7 readonly=\"readonly\";\"<\/td>\n    <td class=\"tg-031e\">ml<\/td>\n  <\/tr>\n    <tr>\n    <td class=\"tg-031e\">Material of tubing (effective compressibility):<\/td>\n    <td class=\"tg-0ord\"><div><select name=\"tubm\"><option value=\"0.0000005\">Steel<option value=\"0.01\">Plastics<option selected value=\"0.1\">Rubber<\/select><\/div><\/td>    \n    <td class=\"tg-031e\"><\/td>\n    <\/tr>\n   \n <\/table>\n\n<table class=\"tg\" style=\"float:left; width:60%\">\n<br>\n<tr>\n    <td class=\"tg-5y5n\">Rise time (approx) of the flow rate of pure water driven by a syringe pump:<\/td>\n    <td class=\"tg-5y5n\"><INPUT STYLE=\"background-color:#ecf4ff; border:1px solid #436bb8; text-align:center; font-weight:bold;\" TYPE =\"text\" NAME=\"stfrsyr\" value=\"934\" size=15 readonly=\"readonly\";\"<\/td>\n    <td class=\"tg-5y5n\">seconds<\/td>\n  <\/tr>\n    <tr>\n    <td class=\"tg-5y5n\">Rise time (approx) of the flow rate of pure water driven by a Precision Pressure Controller P<sup>2<\/sup>CS:<\/td>\n    <td class=\"tg-5y5n\"><INPUT STYLE=\"background-color:#ecf4ff; border:1px solid #436bb8; text-align:center; font-weight:bold;\" TYPE =\"text\" NAME=\"stfrp2cs\" value=\"0.017\" size=15 readonly=\"readonly\";\"<\/td>\n    <td class=\"tg-5y5n\">seconds<\/td>\n   <\/tr>\n   <tr>\n<td class=\"tg-5y5n\">Factor by which the P<sup>2<\/sup>CS is faster than the syringe pump<\/td>\n<td class=\"tg-5y5n\"><INPUT STYLE=\"background-color:#ecf4ff; border:1px solid #436bb8; text-align:center; font-weight:bold;\" TYPE =\"text\" NAME=\"p2csfaster\" value=\"54932\" size=15 readonly=\"readonly\";\"<\/td>\n<td class=\"tg-5y5n\"><\/td>\n<\/tr>\n<\/table>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"de\"\/><\/form>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>We are grateful to Dr. Philippe Marmottant from the\u00a0Laboratoire Interdisciplinaire de Physique (&#8220;LIPhy&#8221;,formerly\u00a0Spectrometrie Physique) CNRS\/Universit\u00e9 Grenoble 1\u00a0for his interesting\u00a0<a href=\"http:\/\/en.wikibooks.org\/wiki\/Microfluidics\/Hydraulic_resistance_and_capacity\" target=\"_blank\" rel=\"noopener noreferrer\">article at\u00a0wikibooks.org<\/a>\u00a0\u00a0on which our model is based.<\/p>\n<p><span style=\"color: #a5a5a5;\">There is no warranty of any kind regarding the accuracy or completeness of this\u00a0calculator\u00a0or your results, and the user assumes all risk of use.<br \/>\nUse of this\u00a0calculator\u00a0constitutes your acceptance of these terms.<\/span><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"You need JavaScript enabled to execute these calculations! P2CS \/ Syringe Pump Comparison Calculator Compare the different stabilization times of syringe pumps and\u00a0our\u00a0Precision Pressure Control System P2CS\u00a0for a set value pressure step of 50mbar with pure water at 25 \u00b0C.\u00a0The calculated time estimates the time to reach 90% of the final flow rate.\u00a0Hysteresis and mechanical&hellip;","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":11,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/pages\/1403"}],"collection":[{"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/comments?post=1403"}],"version-history":[{"count":68,"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/pages\/1403\/revisions"}],"predecessor-version":[{"id":2689,"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/pages\/1403\/revisions\/2689"}],"wp:attachment":[{"href":"https:\/\/biophysical-tools.de\/de\/wp-json\/wp\/v2\/media?parent=1403"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}